WInTeRIZInG
Protect unit utilizing water based formulations from freezing if unit is to
be transported, or stored in an area where freezing is likely. Drain solu-
tion reservoir, and spray some winterized windshield cleaning solution
through unit. Solvent based formulations such as ODORx
®
THERMO 55
do not freeze, so when utilizing solvent based formulations no special
winterizing procedure is necessary.
CloGGInG
Foreign matter in the liquid can result in clogging the pump or nozzle.
To insure proper operation it is recommended that clean formulation
always be utilized, or that it should rst be ltered through paper coffee
lters before use if foreign matter is present or suspected.
Replace nozzle every 8 hours of operation to insure small fog particle size.
PRessURe PURGInG THe MeCHanIsM
Aerosol solvent carburetor cleaner may be used to purge and ush dirty
or clogged pump mechanisms, or for periodic maintenance.
Note: Unit's motor must make normal buzzing sound for this maintenance/
repair technique to be effective.
1. Protect work area from solvent related damages by covering with
newspaper or other absorbent material.
2. Wear protective goggles and rubber gloves.
3. Insert the plastic tube from the aerosol carburetor cleaner into the
can nozzle.
4. Remove formulation reservoir from fogger.
5. Remove formulation lter from brass stem.
6. Disengage heat barrel from fogger. Plug fogger into electrical outlet.
7. Insert straw from aerosol can into white plastic nut at bottom of brass stem.
8. Simultaneously pull trigger on fogger while depressing spray nozzle
on aerosol can to inject a 1 second burst of cleaner into the mecha-
nism to purge and ush system. A stream or spray of cleaner should
be visible at nozzle cap.
9. Fill formulation reservoir with suitable solution, clean formulation lter
and re-install on brass stem, attach formulation reservoir to unit and test operate.
If necessary, repair or replace pump/piston system.